The PowerMaster CSG Slide Gate Operator Kit 4 is a fully equipped, commercial-grade automatic sliding gate solution designed for maximum safety, convenience, and reliable access control. Powered by a 1/2 horsepower motor operating on 115V single-phase power, this kit is ideal for commercial facilities, industrial sites, and high-traffic gated properties.
This comprehensive kit includes a Seco-Larm E-931-S50RRG6Q photo cell safety sensor, Linear 109950 receiver, two 308912 remote transmitters, a wireless keypad (DOL1000MF with Module 300), and an EMX 202-50 Exit Wand vehicle detector. Engineered for continuous-duty performance, the CSG operator delivers smooth gate movement, enhanced safety, and multiple access control options in one complete package.
CSG slide gate operator kit.
1/2HP motor for commercial-grade performance.
115V single-phase power.
Includes E-931-S50RRG6Q photo cell safety sensor.
Includes Linear receiver (109950).
Includes two remote transmitters (308912).
Includes wireless keypad DOL1000MF with Module 300.
Includes EMX Exit Wand vehicle detector (202-50).
Heavy-duty construction for continuous-duty cycles.
Smooth, reliable sliding gate operation.
Compatible with advanced access control and safety devices.
Verify the sliding gate is properly aligned and moves freely.
Disconnect electrical power before installation.
Mount the CSG operator following PowerMaster installation guidelines.
Connect 115V single-phase power per local electrical codes.
Install and align the E-931-S50RRG6Q photo cell sensor.
Install the Linear receiver and program the remote transmitters.
Install and program the wireless keypad (DOL1000MF with Module 300).
Install the EMX Exit Wand (202-50) per manufacturer instructions.
Adjust travel limits and force settings.
Restore power and perform complete operational and safety testing.
Disconnect AC power before installing or servicing the system.
Keep hands, tools, and objects away from moving gate parts.
Photo cell must be properly aligned for safe operation.
Exit wand wiring must follow recommended burial depths.
Only trained technicians should install or repair the system.
Follow local automatic gate safety codes and UL 325 guidelines.
Never allow children or unauthorized users to operate the system.
Add loop detectors for enhanced vehicle safety and reliability.
Test the photo cell, exit wand, remotes, and keypad monthly.
Lubricate rollers, tracks, and moving components every 3–6 months.
Use surge protection for sensor and operator electronics.
Replace battery backup and remote batteries when needed.
Use only PowerMaster/OEM replacement components.